MK4 & Air Wolf - Resetting to defaults
The programming mode is entered by ensuring the gun is unloaded, in the safe position, pointing the muzzle in a safe direction (down) and pulling the trigger, then switch the safety catch to FIRE. The gun will then beep and flash indicating that the gun is in program mode. If the trigger is kept pulled, the gun will cycle through its programming mode and will beep and flash the appropriate amount of times, indicating the mode it is in.
Default Setting
The user can set the gun to a default condition to switch off all the features, programmed in by the user.
Default programming
- Ensure that the gun is unloaded and the safety switch is in the SAFE position
- Ensure the isolator switch is set to on and the gun is pointed in a safe direction. Pull the trigger and then switch the safety switch to FIRE with the trigger still pulled. A red light will be on
- Keep trigger pulled until 8 beeps are heard
- Release the trigger and pull the trigger again once - a long beep will be heard
- Re-apply the Safety catch to the SAFE position
- Defaults have been restored:
- Magazine counter off
- Magazine counter set to zero
- Shot counter off
- Shot count set to zero
- Safety LED normally on
- Power set to maximum